Search results for "D-dimer assay"

showing 2 items of 2 documents

Evaluation of the Stratus® CS Acute Care™ D-dimer assay (DDMR) using the Stratus® CS STAT Fluorometric Analyzer: A prospective multisite study for ex…

2012

Abstract Background D-dimer testing is an integral part of the diagnostic algorithm in excluding patients with venous thromboembolism. In this study, we prospectively evaluated the Stratus DDMR D-dimer test in patients suspected of pulmonary embolism (PE) and deep vein thrombosis (DVT). Methods Patients suspected of venous thromboembolism were prospectively enrolled at four different clinical sites, with sodium citrate and lithium heparin plasma was tested using the DDMR D-dimer test on the Stratus CS analyzer. Results 1,012 patients were enrolled for analysis, with 85/603 (14.1%) patients with PE and 80/443 (18.1%) with DVT, and four of the patients (0.4%) with PE and DVT. For the samples …

Adultmedicine.medical_specialtyDeep veinGastroenterologyD-dimer assayFibrin Fibrinogen Degradation ProductsYoung AdultInternal medicineAcute caremedicineHumansFluorometryProspective Studiescardiovascular diseasesProspective cohort studyAgedAged 80 and overImmunoassayVenous Thrombosisbusiness.industryHematologyHeparinMiddle Agedmedicine.diseaseThrombosisPulmonary embolismSurgerymedicine.anatomical_structurePulmonary EmbolismbusinessVenous thromboembolismmedicine.drugThrombosis Research
researchProduct

International, multicenter evaluation of a new D-dimer assay for the exclusion of venous thromboembolism using standard and age-adjusted cut-offs.

2017

We sought to determine the test characteristics of an automated INNOVANCE D-dimer assay for the exclusion of pulmonary embolism (PE) and deep venous thrombosis (DVT) in emergency department (ED) patients using standard and age-adjusted cut-offs.Cross-sectional, international, multicenter study of consecutive patients with suspected DVT or PE in 24 centers (18 USA, 6 Europe). Evaluated patients had low or intermediate Wells PE or DVT scores. For the standard cut-off, a D-dimer result500 ng/ml was negative. For the age adjusted cut-off, we used the formula: Age (years) ∗ 10. The diagnostic standard was imaging demonstrating PE or DVT within 3 months. We calculated test characteristics using s…

Malemedicine.medical_specialtyAge adjustment030204 cardiovascular system & hematologyD-dimer assayFibrin Fibrinogen Degradation Products03 medical and health sciences0302 clinical medicinePredictive Value of TestsInternal medicinemedicineHumanscardiovascular diseases030212 general & internal medicinebusiness.industryAge FactorsHematologyEmergency departmentVenous ThromboembolismMiddle Agedmedicine.diseasePulmonary embolismVenous thrombosisCross-Sectional StudiesMulticenter studyDecreased SensitivityBiological AssayFemalebusinessVenous thromboembolismThrombosis research
researchProduct